JURNAL SIMETRIK (Sipil. Mesin. Listri. https://ejournal-polnam. id/index. php/JurnalSimetrik Online ISSN: 2581-2866 https://creativecommons. org/licenses/by-nc/4. DESAIN PEMBANGKIT LISTRIK TENAGA SURYA (PLTS) OFFGRID DUSUN I NEGERI HUTUMURI Chelsya Matakena. Lory Marcus Parera. Marselin Jamlaay. 1,2,3. Jurusan Teknik Elektro Politeknik Negeri Ambon chelsyamatakena@gmail. com , 2lorymarc8@gmail. com , 3 marselin@gmail. ARTICLE HISTORY Received: August 9, 2025 Revised November 11, 2025 Accepted: November 13, 2025 Online available: November 24, 2025 Keywords: PLTS Off-Grid. DOD. MPPT *Correspondence: Name: Chelsya Matakena E-mail: chelsyamatakena@gmail. ABSTRACT This research aims to design an Off-Grid Solar Power Plant (PLTS) in Dusun I Negeri Hutumuri, to overcome the limited electricity supply from PLN which often experiences periodic blackouts. Off-Grid PLTS was chosen as an alternative solution because it uses abundant solar energy in the region, is environmentally friendly, and does not depend on conventional power grids. This research begins with an analysis of the daily load requirements in Dusun I Negeri Hutumuri, which include household needs, public facilities such as schools and health centers, with total energy consumption reaching 605. 064 kWh. In the design of this Off-Grid PLTS system, the main components used include solar modules, batteries, and inverters. The peak capacity required for this solar system is 172 kWp with a total energy of 168,073 Wh. Based on the calculation results, this system uses 210 solar modules connected in a series-parallel configuration, as well as five inverters with a capacity of 20 kW each. Keywords: PLTS Off-Grid. DOD. MPPT Kantor Editorial Politeknik Negeri Ambon Pusat Penelitian dan Pengabdian Masyarakat Jalan Ir. Putuhena. WailelaRumahtiga. Ambon Maluku. Indonesia Kode Pos: 97234 PENDAHULUAN Listrik merupakan kebutuhan primer manusia saat ini. Kegiatan manusia yang berhubungan dengan pengoperasian peralatan bergantung pada ketersediaan Kebutuhan akan listrik terus bertambah sejalan dengan berkembangan teknologi dan pertambahan jumlah penduduk. Pembangunan suatu daerah akan semakin berdaya dengan adanya sumber energi Listrik yang tidak hanya menyediakan kebutuhan dasar, tetapi juga menjadi pendorong utama dalam menciptakan kemajuan ekonomi dan kesejahteraan bagi (Ammar et al. , 2. Sumber energi baru terbarukan memiliki peran penting di masa yang akan datang serta mampu dalam memenuhi kebutuhan energi suatu bangsa. Hal ini menjadi tantangan tersendiri, terutama di daerahChelsya Matakena et. DOI: https://doi. org/10. 31959/js. daerah terpencil yang sulit dijangkau oleh jaringan listrik konvensional. Daerah dusun 1 Negeri Hutumuri sudah tersuplai jaringan listrik PLN namun dalam pelaksanaannya belum optimal karena dalam seminggu jaringan listrik PLN pada daerah tersebut bisa dipadamkan 2-3 jam per hari bahkan lebih dari 3 jam maka diperlukan solusi yang dapat diterapkan adalah dengan mengembangkan sistem pembangkit listrik tenaga surya (PLTS) off-grid. Dalam perancangan PLTS perlu diperhatikan penggunaan beban harian pada lokasi/area terpasang. Estimasi beban harian penting dalam merancang sistem pembangkit listrik, termasuk sistem energi terbarukan seperti PLTS Off-Grid, untuk memastikan bahwa kapasitas pembangkit listrik memadai untuk memenuhi kebutuhan energi harian tersebut. Berdasarkan latar belakang tersebut penulis akan melakukan penelitian Desain Pembangkit Listrik Tenaga Surya A JURNAL SIMETRIK (Sipil. Mesin. Listri. https://ejournal-polnam. id/index. php/JurnalSimetrik Online ISSN: 2581-2866 https://creativecommons. org/licenses/by-nc/4. dengan judul AuDesain Pembangkit Listrik Tenaga Surya Off-Grid Dusun I Negeri Hutumuri Ay TINJAUAN PUSTAKA 1 Pembangkit Listrik Tenaga Surya PLTS adalah suatu pembangkit listrik yang menggunakan sinar matahari melalui sel surya . untuk mengkonversikan radiasi sinar foton matahari menjadi energi listrik. Unjuk kerja PLTS sangat dipengaruhi oleh beberapa faktor yaitu faktor lingkungan, faktor temperatur PV modul, faktor kondisi cuaca lingkungan dan faktor Intensitas cahaya (Anggara et al. , 2. Perhitungan sistem Pembangkit Listrik Tenaga surya (PLTS) Sebagai Berikut: Kapasitas sistem PLTS dapat dihitung dengan rumus berikut: Kapasitas Sistem PLTS . = ycoycOEa yaycOycy yayc ycEycO ycCycyc ( Dimana: PV Out = Kapasitas PLTS = Konsumsi Energi listrik harian = Daya keluaran PV per KWp Yang diperoleh berdasarkan besaran iradiasi matahari menyebabkan biaya investasi pengembangan jaringan listrik atau pembangkit konvensional menjadi sangat besar, serta biaya operasional dan pemeliharaan yang terbatas akibat minimnya akses transportasi ke wilayah Sistem PLTS Off-Grid mengandalkan energi matahari sebagai satu-satunya sumber listrik, sehingga ramah lingkungan dan tidak mencemari udara. PLTS Off-Grid menjadi solusi terbaik dalam penyediaan energi listrik di daerah terpencil dengan memanfaatkan energi matahari yang dikonversi menjadi listrik untuk memenuhi kebutuhan masyarakat. Sistem ini juga memiliki keunggulan dalam hal pengoperasian dan perawatan yang sederhana, serta dapat berfungsi hingga 10 tahun tanpa perlu penggantian peralatan. (Rahayuningtyas , 2. 3 Sistem Pembangkit Listrik Tenaga Surya OffGrid Sistem Pembangkit Listrik Tenaga Surya (OffGri. merupakan sistem pembangkit listrik yang memanfaatkan radiasi matahari tanpa terhubung dengan jaringan PLN. Dengan kata lain, sumber energinya hanya berasal dari radiasi matahari yang dikonversi menjadi energi listrik melalui panel surya atau photovoltaic. Sistem PLTS Off-Grid ini umumnya digunakan di daerah yang belum terjangkau pasokan listrik dari PLN, seperti daerah pedesaan. (Hasanah et , 2. Daya puncak sistem PLTS dihitung dengan rumus Daya Puncak . = Wp (Wp x Rugi-rugi sistem (%)). Dimana kWp = Daya puncak PLTS Wp = Kapasitas Optimal PLTS Luas area efektif PLTS dihitung dengan rumus ycOycy Luas Area . yayceycnycycnyceycuycycn ycAycuyccycyco ycEycO Dimana: m2 = luas area PLTS Wp = daya puncak PLTS 2 Sistem Kelistrikan Off-Grid Sistem Pembangkit Listrik Tenaga Surya (PLTS) Off-Grid merupakan sistem pembangkit listrik alternatif yang ditujukan untuk daerah-daerah terpencil atau pedesaan yang belum terjangkau oleh jaringan listrik PLN. Sulitnya akses dan mobilisasi ke lokasi Chelsya Matakena et. kataA DOI: https://doi. org/10. 31959/js. Gambar 1 Skema PLTS Off-Grid (Sumber : Manab et al. , 2. 4 Penyambungan Sistem PLTS Off-Grid Konfigurasi DC Coupling Sistem DC Coupling terkoneksi ke sisi arus searah (DC) dari sistem kelistrikan PLTS off-grid. Pada sistem ini charge controller mengatur energi matahari yang terserap oleh array modul surya melalui MPPT. Energi keluaran dari charge controller terhubung melalui busbar DC ke sistem baterai sebagai penyimpan energi. Baterai terhubung ke inverter yang bertugas Judul: 6 Halaman JURNAL SIMETRIK (Sipil. Mesin. Listri. https://ejournal-polnam. id/index. php/JurnalSimetrik Online ISSN: 2581-2866 https://creativecommons. org/licenses/by-nc/4. mengkonversi arus searah (DC) ke aru bolakbalik (AC) di alirkan dari inverter ke beban AC (Tan et al. , 2. Konfigurasi memanfaatkan radiasi matahari pada siang hari untuk disimpan dalam baterai utnuk mencapai kondisi pengisian baterai yang maksimal (State Of Charg. Ketika beban meningkat dan melebihi daya yang tersalurkan langsung ke beban, energy listrik akan disalurkan oleh inverter yang mengkonversikan tegangan DC menjadi AC sampai batas minimum dari state of charge (SoC) baterai. (Sumber : Latasya et al. ,2. 5 Komponen Pembangkit Listrik Tenaga Surya Panel surya Komponen utama dalam sistem PLTS adalah panel surya yang merupakan rakitan dari beberapa sel surya. Sel surya tersusun dari dua lapisan semi konduktor dengan muatan Lapisan atas sel surya itu bermuatan bermuatan positif. Sel-sel itu dipasang dengan posisi sejajar dan seri dalam sebuah panel yang terbuat dari alumunium ataupun baja anti karat yang dilindungi oleh kaca atau plastik. Gambar 2 Konfigurasi DC Coupling (Sumber : Latasya et al. ,2. Konfigurasi AC Coupling Perbedaan yang paling signifikan dari sistem DC coupling dengan AC coupling ialah keberadaan inverter jaringan. Pada AC menghubungkan PV array dan baterai di bus AC. Inverter jaringan memiliki perangkat MPPT (Maximum Power Point Tracke. untuk memaksimalkan daya input yang diterima dari PV array disalurkan ke beban dan disimpan ke baterai. Pada siang hari, energi listrik yang dihasilkan oleh PV Array dapat langsung digunakan oleh beban dan daya yang lebih akan disimpan dalam baterai ( Latasya et al. , 2. Gambar 4 Panel Surya (Sumber : Ammar et al. , 2. Solar Charge Controller Solar Charge Controller adalah alat yang digunakan untuk mengontrol proses pengisian muatan listrik dari panel surya ke aki dan Terdapat setidaknya dua jenis solar controller yaitu yang menggunakan teknologi PWM . ulse width modulatio. dan MPPT . aximum power point trackin. (Naim. SCC yang dipilih ialah jenis Maximum Power Point Tracking (MPPT). SCC jenis ini dapat beroperasi di atas tegangan baterai, sehingga dapat mendorong pengisian lebih cepat pada kondisi temperatur dingin dan kapasitas baterai rendah. (Hakim et al. Gambar 3 Konfigurasi DC Coupling Chelsya Matakena et. kataA DOI: https://doi. org/10. 31959/js. Judul: 6 Halaman JURNAL SIMETRIK (Sipil. Mesin. Listri. https://ejournal-polnam. id/index. php/JurnalSimetrik Online ISSN: 2581-2866 https://creativecommons. org/licenses/by-nc/4. film tipis. Lapisan film ini disusun berlapis-lapis diantara anoda dan katoda yang mengakibatkan pertukaran ion. Dengan metode ini baterai LiPo dapat dibuat dalam berbagai bentuk dan Diluar dari kelebihan arsitektur baterai LiPo, terdapat juga kekurangan yaitu lemahnya aliran pertukaran ion yang terjadi melalui elektrolit polimer Hal ini menyebabkan penurunan pada charging dan discharging rate. Masalah ini sebenarnya bisa diatasi dengan memanaskan baterai sehingga menyebabkan pertukaran ion menjadi lebih cepat, namun metode ini dianggap tidak dapat untuk diaplikasikan pada keadaan sehari-hari. Seandainya para ilmuwan dapat memecahkan masalah ini maka risiko keamanan pada batera jenis lithium akan sangat berkurang. Baterei Lead Acid (Acc. Baterai Lead Acid (Acc. Baterai Lead Acid atau biasa disebut aki merupakan menggunakan asam timbal . ead aci. sebagai bahan kimianya. Secara umum terdapat dua jenis baterai lead-acid, yaitu : . Starting Battery, dan . Deep Cycle Battery . Baterei Nickel-Metal Hydride (Ni-MH) Baterai jenis ini dibuat engan komponen yang lebih terjangkau dan ramah Baterai Ni-MH menggunakan ion hidrogen untuk menyimpan energi, tidak seperti baterai lithium ion yang menggunakan ion Baterai Ni-MH terdiri dari campuran nikel dan logam lain seperti Baterai mengandung pula komponen logam lain seperti mangan, aluminium, kobalt, zirconium, dan vanadium. Logamlogam tersebut pada umunya berfungsi sebagai penangkap ion hidrogen yang dilepaskan untuk memastikan tidak mencapi fase gas. Gambar 5 Solar Charge Controller (Sumber : Wasistha et al. , 2. Baterei Baterai adalah komponen yang menyimpan energi listrik yang dihasilkan oleh panel surya yang menyerap sinar matahari. baterai dapat cadangan energi mengimbangi kekurangan energi. ketika permintaan listrik melebihi output panel surya. Baterai timbal alami dan baterai nikel kadmium adalah dua jenis baterai isi ulang yang dapat digunakan dalam sistem tenaga surya. Ada 2 jenis baterei yang di gunakan di pasaran yaitu: Primary battery baterei yang hanya dapat digunakan sekali saja dan dibuang. Material elektrodannya tidak dapat berkebalikan arah Ketika dilepaskan. Secondary battery baterei yang dapat digunakan dan diisi ulang beberapa kali, proses kimia yang terjadi di dalam baterei ada reversible , dan bahan aktif dapat kembali ke kondisi semula dengan pengisian sel. Baterei sekunder terdapat banyak jenis di pasaran , antara lain : ( Afif et , 2. Baterei ion litium ( Li-ion atau LIB) Di dalam baterei ini, ion litium bergerak dari elektroda negative ke elektroda positif saat dilepaskan , dan kembali saat di isi ulang. Batarei Lithium Polymer (Li-P. Hampir sama dengan baterai Li- Ion akan tetapi baterai Li-Po tidak menggunakan cairan sebagai elektrolit melainkan menggunakan elektrolit polimer kering yang berbentuk seperti lapisan plastik Chelsya Matakena et. kataA DOI: https://doi. org/10. 31959/js. Untuk menentukan kapasitas baterei , dapat dihitung menggunakan rumus berikut: (Manab et al. , 2. ycoycaycyycaycycnycycayc yaAycaycyceycyceycn = ycycycoycoycaEa ycoyceycaycycycEaycaycu ycu ycycycoycoycaEa Eaycaycycn ycycaycuycyyca ycoycaycycaEaycaycycn yaycCya Judul: 6 Halaman JURNAL SIMETRIK (Sipil. Mesin. Listri. https://ejournal-polnam. id/index. php/JurnalSimetrik Online ISSN: 2581-2866 https://creativecommons. org/licenses/by-nc/4. Beban harian mengacu pada total kebutuhan energi listrik yang dikonsumsi oleh suatu lokasi atau ycoycaycyycaycycnycycayc yaycoycyOeEaycuycyc rumah tangga dalam satu hari. Hal ini mencakup A ycycycoycoycaEa yaAycaycyceycyceycn yccycnEaycycaycycuyci ycyceycycn = penggunaan peralatan rumah tangga seperti lampu. AC, ycyceyciycaycuyciycaycu yaycuycyceycycyceyc kulkas, oven, dan perangkat lainnya, serta kebutuhan A ycNycuycycayco yaAycaycyceycyceycn = energi untuk kegiatan sehari-hari seperti memasak, ycycycoycoycaEa yaAycaycyceycyceycn ycyycaycycaycoyceyco ycu yaycycoycoycaEa yaAycaycyceycyceycn ycyceycycnmencuci, dan penggunaan perangkat elektronik. A ycNycuycycayco ycoycaycyycaycycnycycayc yaycoycy ycaycaycyceycyceycn = Estimasi beban harian sangat penting dalam merancang ycycycoycoycaEa yaAycaycyceycyceycn ycyycaycycaycoyceyco ycu ycoycaycyycaycycnycycayc yaycoycy Oe sistem pembangkit listrik, termasuk sistem energi Eaycuycyc terbarukan seperti PLTS Off-Grid, untuk memastikan A ycNycuycycayco ycoycaycyycaycycnycycayc ycoycOEa yaAycaycyceycyceycn = kapasitas pembangkit memadai dalam memenuhi ycycuycycayco ycoycaycyycaycycnycycayc yaycoycy yaAycaycyceycyceycn ycu ycyceyciycaycuyciycaycu ycnycuycyceycycyceyc kebutuhan energi harian tersebut. ycycycoycoycaEa yaAycaycyceycyceycn yccycnEaycycaycycuyci ycyycaycycaycoyceyco = ycoycaycyycaycycnycycayc yaAycaycyceycyceycn Gambar 6 Baterei (Sumber : Wasistha et al. , 2. Inverter Bagian elektronik yang disebut inverter membantu panel PV mengubah arus searah (DC) menjadi arus bolak-balik (AC), yang merupakan kebutuhan sebagian besar peralatan listrik. Sistem itu sendiri serta persyaratan beban menentukan inverter mana yang paling cocok untuk aplikasi tertentu. apakah sistem tersebut merupakan sistem yang berdiri sendiri atau yang terhubung ke jaringan listrik . rid-connecte. METODOLOGI Penelitian ini akan dilaksanakan di Dusun I Negeri Hutumuri yang beralamat di Jalan Dr. Wem Tehupiorry. Kecamatan Leitimur Selatan. Kota Ambon. Maluku. Waktu pelaksanaan penelitian direncanakan berlangsung selama 1 hingga 2 bulan di lokasi tersebut. Pengumpulan data dilakukan secara langsung, meliputi informasi mengenai peralatan listrik, waktu operasional peralatan, daya terpasang, serta data iradiasi matahari (PV Outpu. Data diperoleh melalui kajian literatur dengan mengambil referensi dari berbagai jurnal dan buku, serta melalui survei lapangan dan wawancara dengan warga Dusun I Negeri Hutumuri. Metode analisis yang digunakan meliputi perhitungan manual dan perhitungan menggunakan Microsoft Excel terhadap data primer dan sekunder. Perhitungan manual digunakan untuk menentukan kapasitas PLTS, kapasitas inverter, dan kapasitas baterai pada sistem PLTS Off-Grid. Sementara itu, perhitungan menggunakan Microsoft Excel digunakan untuk menghitung beban harian. HASIL DAN PEMBAHASAN Hasil Penelitian 1 Gambaran Umum Lokasi Penelitian Dusun I Negeri Hutumuri terletak di wilayah yang relatif dekat dengan pusat kota, tepatnya di Kecamatan Leitimur Selatan. Kota Ambon, yang terdiri dari empat dusun. Berdasarkan hasil pengambilan data. Dusun I Negeri Hutumuri memiliki jumlah kepala keluarga sebanyak 70 dengan total jumlah penduduk sekitar 300 jiwa. Gambar 7 Inverter (Sumber : Ramadhan Ch. Rangkuti, 2. 6 Beban Harian Chelsya Matakena et. kataA DOI: https://doi. org/10. 31959/js. Meskipun wilayah ini telah tersuplai jaringan listrik dari PLN, namun penyediaan listrik belum berjalan secara optimal. Dalam satu minggu, pemadaman listrik dapat terjadi selama 2Ae3 jam per hari, bahkan terkadang lebih dari 3 jam. Oleh karena Judul: 6 Halaman JURNAL SIMETRIK (Sipil. Mesin. Listri. https://ejournal-polnam. id/index. php/JurnalSimetrik Online ISSN: 2581-2866 https://creativecommons. org/licenses/by-nc/4. itu, diperlukan solusi alternatif berupa pengembangan sistem Pembangkit Listrik Tenaga Surya (PLTS) OffGrid yang dapat membantu memenuhi kebutuhan listrik masyarakat secara mandiri dan berkelanjutan. 2 Data Beban Tabel 1. Perhitungan Beban Harian Nama Beban Total Energi (W. Rumah Warga PJU Sekolah SD Sekolah SMP Sekolah SMA Puskesmas Sumber: Chelsya Matakena ,2024 Berdasarkan tabel perhitungan beban harian pada Dusun I Negeri Hutumuri maka, total konsumsi energi yaitu 605064 Wh . ,064 kW. 3 PVout Iradiasi Matahari Pada Dusun I Negeri Hutumuri PVOut merupakan hasil perhitungan daya keluaran PV per KWp Yang diperoleh berdasarkan besaran iradiasi matahari . data PVOut dapat diperoleh di . info/ma. Specific Photovoltaic Power Output (PVOUT): Menunjukkan output tenaga listrik per hari yang dapat dihasilkan per meter persegi panel surya, dengan nilai 3. kWh/kWp. Direct Normal Irradiation (DNI): Radiasi langsung matahari yang diterima, 3. kWh/mA. Global Horizontal Irradiation (GHI): Radiasi matahari total yang diterima pada permukaan horizontal, 4. 850 kWh/mA. Diffuse Horizontal Irradiation (DIF): Radiasi tersebar yang diterima pada permukaan horizontal, 2. 243 kWh/mA. Global Tilted Irradiation (GTI): Radiasi yang diterima oleh panel yang dipasang pada sudut optimal, 4. 851 kWh/mA. Optimum Tilt of PV Modules: Sudut optimal pemasangan modul surya, sebesar 2A. Air Temperature (TEMP): Suhu udara ratarata di lokasi, yaitu 26. 3AC. Elevation (ELE): Ketinggian lokasi dari permukaan laut, yaitu 2 meter. Pembahasan 1 Perhitungan Perancangan Sistem PLTS OffGrid Menetukan Kapasitas sistem PLTS dapat di hitung dengan rumus berikut: ycoycOEa kWp= ycoycOycy ycEycO ycCycyc ( ycoyc 605,064 ycoycOycy yayc 3,861 ( = 156,71 kWp . 710 W. Daya Puncak sistem PLTS dapat dihitung dengan rumus berikut: kWp = Wp (Wp x Rugi-rugi Sistem (%)) Gambar 8 PV Out Iradiasi Matahari (Sumber : Global Solar Atla. Gambar 8 di dapatkan dari Global Solar Atlas yang menunjukkan potensi energi surya di daerah Ambon. Maluku. Indonesia yang berlokasi di Dusun I Negeri Hutumuri. Berikut penjelasan dari informasi yang terlihat pada gambar: 1 Lokasi Koordinat: Lokasi Dusun I Negeri Hutumuri ditandai dengan koordinat -3. (Lintang Selata. 278713A (Bujur Timu. Zona Waktu: UTC 9:00 (Waktu Indonesia Timu. 2 Data Potensi Energi Surya: Di sebelah kanan, terdapat informasi mengenai data spesifik tentang potensi energi surya di lokasi tersebut, termasuk: Chelsya Matakena et. kataA DOI: https://doi. org/10. 31959/js. = 156710 . 710 x 10%) = 172381 Wp . Luas area efektif PLTS dihitung dengan rumus Luas Area . =Wp / (Efisiensi Modul PV) =. 381 )/. ,37%) = 846,24 m Menetukan kapasitas inverter baterei Menentukan kapasitas inverter untuk baterei adalah proses menghitung atau memilih ukuran inverter dan baterei yang sesuai untuk kebutuhan tertentu. Kapasitas inverter mengacu pada daya maksimal yang dapat di suplai oleh inverter , sementara kapasitas baterei mengacu pada jumlah energi yang dapat disimpan dan di suplai oleh baterei. Judul: 6 Halaman JURNAL SIMETRIK (Sipil. Mesin. Listri. https://ejournal-polnam. id/index. php/JurnalSimetrik Online ISSN: 2581-2866 https://creativecommons. org/licenses/by-nc/4. Perhitungan kapasitas pembangkit yaitu proses untuk menentukan seberapa besar kapasitas daya yang harus dihasilkan oleh sebuah sistem pembangkit listrik. Tabel 2. Kapasitas Inverter Baterei Efisiensi Inverter 0,95 Tegangan Inverter sistem ,24,48 V) Keluaran tegangan inverter 230 ,230,240 V) Jumlah Energi Beban / hari 605064 Jumlah kebutuhan Ah 12605,50 beban / hari Sumber: Chelsya Matakena ,2024 Volt Volt Wh / hari Ah / hari Perhitungan Kapasitas dan Jumlah Baterei Dalam suatu sistem energi di lakukan berdasarkan total kebutuhan daya dan waktu operasional yang Tabel 3. Perhitungan Kapasitas dan Jumlah Baterei Jumlah hari tanpa DOD Kapasitas baterei Kapasitas Amp-Hour /100/1000 Jumlah baterei di hubung Jumlah baterei di hubung Jumlah total baterei Total kapasitas Amp/Hour baterei Total kapasitas Kwh Sumber: Chelsya Matakena ,2024 Hari Tabel 4. Perhitungan Kapasitas Pembangkit Jumlah Total Kebutuhan energi / hari Keluaran Energi rangkaian Modul Tegangan Modul Daya Maximum (STC) Daya Maximum Modul (STC) Jam Matahari Pada Bulan Keluaran Energi Modul Surya / hari Keluaran Energi pada Temperature Operasi Temperature Ambient Jumlah Modul surya untuk Kebutuhan Beban Kapasitas Pembangkit Total Kapasitas PLTS Sumber: Chelsya Matakena ,2024 41,40 Volt Watt Jam 0,45 AC Modul 2 Single Line Diagram Buah Buah Buah Perhitungan Modul seri minimum dan maksimum Perhitungan modul seri minimum dan maksimum dalam system energi surya . berkaitan dengan berapa banyak panel surya yang perlu dihubungan secara seri dalam satu rangkaian untuk memastikan tegangan yang tepat untuk sistem tersebut. Jumlah modul seri minimum yaitu 2 modul , jumlah modul seri maksimum yaitu 41 modul. Jumlah string seri maksimum yaitu 7 dan Jumlah string paralel Setiap sub array terdapat 42 modul PV 450 Wp yang terhubung seri dan paralel. Perhitungan Kapasitas pembangkit Chelsya Matakena et. kataA DOI: https://doi. org/10. 31959/js. Gambar 9 Single Line PLTS Off-Grid Sumber: Chelsya Matakena ,2024 Pada gambar 9 jumlah Modul PV yang akan di pasang pada Dusun I Negeri Hutumuri yaitu 210 unit dan inverter 5 unit. Setiap sub array terdapat 42 unit Modul PV 450 Wp yang terhubung seri dan paralel. Jumlah modul pada 1 string seri yaitu 7 dan jumlah modul pada 1 string paralel yaitu 6 dan setiap string menggunakan 1 inverter 20 kW dan baterei yang digunakan sebanyak 756 buah dimana jumlah baterei dihubung paralel sebanyak 32 buah dan jumlah baterei di hubung seri yaitu 24 buah. Judul: 6 Halaman JURNAL SIMETRIK (Sipil. Mesin. Listri. https://ejournal-polnam. id/index. php/JurnalSimetrik Online ISSN: 2581-2866 https://creativecommons. org/licenses/by-nc/4. 3 Implementasi Pada penelitian ini konsumsi energi pada Dusun I Negeri Hutumuri sebesar 605,064 kWh, daya puncak sistem PLTS sebesar 172 kWp, total kapasitas pembangkit yaitu 168073 Wh . , dan total kapasitas PLTS yaitu 95 kWp. Dari Hasil perhitungan luasan dusun I Negeri Hutumuri maka jumlah modul surya yang digunakan yaitu 210 unit dengan 7 string seri dan 6 string paralel. setiap string terdapat 42 modul pv yang dihubungkan seri dan penggunaan inverter 20 kW. PENUTUP Kesimpulan Berdasarkan perhitungan dan analisis yang telah dilakukan, maka dapat ditarik kesimpulan sebagai Perhitungan Beban Harian pada Dusun I Negeri Hutumuri menunjukkan total komsumsi energi listrik sebesar 605,064 kWh. Ini mencakup kebutuhan listrik rumah warga, penerangan jalan umum (PJU), sekolah, dan puskesmas . ini menjadi dasar untuk menentukan kapasitas PLTS untuk dapat memenuhi kebutuhan energi Total kapasitas PLTS di dusun 1 sebesar 95 kWp, dengan kapsaitas inverter 20 kW yang terdiri dari 5 buah inverter. Saran Pada penelitian selanjutnya desain PLTS ini diharapkan dapat mempertimbangkan kondisi yang ada pada dusun 1 Negeri Hutumuri sehingga dapat menghasilkan desain PLTS yang baik untuk dapat ditingkatkan sesuai dengan pertumbuhan komsumsi listrik di masa depan,dan dapat dijadikan penggunaan energi alternatif sebagai sumber energi pada bangunan umum atau instansi pemerintahan. DAFTAR PUSTAKA