International Journal of Electrical and Computer Engineering (IJECE) Vol. No. August 2017, pp. ISSN: 2088-8708. DOI: 10. 11591/ijece. Optimal Sizing and Economical Analysis of PV-Wind Hybrid Power System for Water Irrigation using Genetic Algorithm Ninet Mohamed Ahmed. Hanaa Mohamed Farghally. Faten Hosney Fahmy Department of Photovoltaic cells. Electronics Research Institute. Giza. Egypt Article Info ABSTRACT Article history: In the present study three renewable power systems are proposed to select the most optimum one for powering an irrigation pumping system and a farmerAos house in two different locations in Sinai. Egypt. Abu-Rudies in south Sinai and El-Arish in north Sinai are the two selected locations. The three suggested power systems are. standalone photovoltaic (PV) system, standalone wind system and standalone PV-wind hybrid system. HOGA (Hybrid Optimization by Genetic Algorithm. simulation software tool based on genetic algorithm (GA) is used for sizing, optimization and economical evaluation of three suggested renewable power systems. Optimization of the power system is based on the components sizing and the operational strategy. The calculated maximum amount of water required for irrigating ten acres of olive per day is 170 m3. In terms of cost effectiveness, the optimal configurations are the hybrid PV-wind system and the standalone PV system for Abu-Rudies and El-Arish locations respectively. These systems are the most suitable than the others for the selected sites metrological data and the suggested electrical load. Received Mar 2, 2017 Revised May 9, 2017 Accepted May 23, 2017 Keyword: Genetic algorithm HOGA Irrigation NPC Photovoltaic Rainwater Wind Copyright A 2017 Institute of Advanced Engineering and Science. All rights reserved. Corresponding Author: Ninet Mohamed Ahmed. Department of Photovoltaic. Electronics Research Institute. El-Bohous St. Previously El-Tahrir St. -Dokki. Giza. Egypt. Email: ninet@eri. eg, ninet321@yahoo. INTRODUCTION Nowadays, water resources of the world have been limited due to global climatic changes. Water shortage is the main characteristic of agriculture on the Mediterranean southern coast, which induces plant water deficits during the dry spring-summer period. In addition, it is the major constraint to expand the agricultural area which is essential to narrow the countryAos food gap . Accordingly, seeking and exploit alternative available water sources have become necessary. Rainwater is one of the available water sources that can be exploited for irrigation . One of the proposed solutions is harvesting and storing rainwater during rainy season by constructing any of the proper reservoir structures. The stored rain water can be used as a great alternative to treated drinking water for irrigation . Because rainfall is scarce in arid regions, it is best to select plants with low water requirements and control planting densities to reduce overall water need. Native plants are well-adapted to seasonal, short-lived water supplies. Olive is widely cultivated in semiarid areas with Mediterranean climate, where long periods of soil water deficit are usually present during the dry season . , . Olive tree has been traditionally grown under rain-fed conditions and is considered one of the best adapted species to the semiarid environment. However, under this condition it usually shows a decrease in photosynthesis that reduces root growth. The introduction of irrigation in olive groves can be attaining considerable increases in olive production. Irrigation, even at rates which are relatively small compared to Journal homepage: http://iaesjournal. com/online/index. php/IJECE A ISSN: 2088-8708 those used for other crops, can raise olive production, in some cases by a factor of six compared to the dryland output . Olive production plays an important role in the economy of many Mediterranean countries and it is considered one of the important crops in Egypt. The Egyptian government supports the cultivation of Sinai olive to increase production and attention to its quality especially after the global standing occupied by Sinai olive worldwide. Therefore, two different locations in Sinai with different meteorological conditions are selected for cultivation ten acres of olive that irrigated by harvest rainwater. Olives have many proven health benefits. it is used for good nutritional . s fresh pickling and for oil productio. and medical purposes. The health benefits of olive oil include treatment for cancers of the colon, breast and stomach. In addition to its benefits for treatment diabetes, heart problems, arthritis pain, high cholesterol, metabolism and digestion . The widely utilization of water pumping systems for irrigation applications with attention of scarcity of fossil resources used in traditional water pumping systems, pricesAo rise and undesirable environmental impacts, it seems essential to replace them with new energy sources. Renewable energies exploit energy sources of natural origin . un, wind, water. They represent energies of future in the measure where they are inexhaustible and preserve the environment . Wind and solar systems in form of hybrid systems can operate as independent power provider, which can supply loads without connecting to the network and island mode . Small scale renewable power system can make a significant contribution for pumping operation in agriculture . , . This paper presents an economic optimization methodology using Genetic Algorithms (GA) for standalone PV system, standalone wind system and standalone PV-wind hybrid system for powering an irrigating pumping system and a farmerAos house. Abu-Rudies and El-Arish regions in Sinai. Egypt are the two sites under consideration. The optimization has been carried out using HOGA, the powerful software tool which successfully determined the best technical and economic system to adopt for the site . An irrigation pump of 1. 5 kW and a discharge rate of 34 m3/h is used for irrigating ten acres of olive in Abu-Rudies and El-Arish regions to increase their productivity and hence to contribute on the economic development. SYSTEM COMPONENTS For the optimization and economical evaluation of renewable power systems, it is required to provide the availability of renewable energy sources over a period of one year. The details of the selected components such as technical and economical data must be entered. The cost of each component includes capital cost, replacement cost, operation and maintenance cost. Also, the detailed data of the electrical load should be identified. The block diagram of the suggested PV-wind hybrid system which is considered in this paper is shown in Figure 1. It consists of solar PV array, wind turbines, battery bank and inverter. The costs and specifications of different system components are shown in Table 1. Table 2. Table 3 and Table 4 PV Array Wind Turbines Charge Regulator Battery Bank Inverter AC Load Figure 1. Block diagram of the suggested PV-wind hybrid system Table 1. PV modules costs and specifications Type Nominal voltage (V) Panel 1 Panel 2 Panel 3 Short (A) Nominal power (W. Acquisition cost($) Replacement cost($) Operation and maintenance cost per year ($/yea. Life span . Null Null Null IJECE Vol. No. August 2017 : 1797 Ae 1814 IJECE ISSN: 2088-8708 Table 2. Wind turbines costs and specifications Type WT1 WT2 WT3 Nominal power (W. Acquisition cost($) Nominal capacity(A. Voltage (V) Nominal power . VA) Acquisition cost($) Replacement cost($) Null Null Null Operation and maintenance cost per year ($/yea. Life span . Table 3. Batteries costs and specifications Type Battery 1 Battery 2 Battery 3 Battery 4 Acquisition cost($) Replacement cost($) Maintenance cost per year ($/yea. Life span . Efficiency (%) Lifespan Table 4. Inverters costs and specifications Type Inverter 1 Inverter 2 Inverter 3 Inverter 4 Replacement cost($) Maintenance cost per year ($/yea. RESOURCES DATA The first step for determining the optimal configuration of the suggested renewable power systems is studying the availability of solar and wind energy sources at a particular location. The annual data of wind speed and solar radiation for Abu-Rudies and El-Arish locations are presented in the following sections. Abu-Rudies Location Abu -Radius region was exposed every year to heavy rain and torrents leading to a heavy financial losses and human damages. This water is flowing and stored in a lake, it is estimated to ranging from 8 to 12 million cubic meters which can be utilized for the purposes of agriculture. This water can be used for irrigating a farm of ten acres of olive. Abu-Rudies is located in the south of the Sinai at 28o 53' N latitude and 33A 11' E longitude with annual average wind speed of 4. 5 m/s and annual average solar radiation of 6. KWh/mA/day. The yearly wind speed and yearly solar radiation of Abu-Rudies region are shown in Figure 2 and Figure 3 respectively . Scaled data Baseline data Scaled data Baseline data Solar Radiation . W/mA) Wind Speed . Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Figure 2. Abu-Rudies yearly wind speed variation Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Figure 3. Abu-Rudies yearly solar radiation variation El-Arish Location El-Arish is located in the north of the Sinai. El-Arish is one of the main water storage areas. especially this place is characterized by very prolific rain. In addition, it has rainwater harvesting projects, which is the collecting of falling water from over the mountains and stored in dams and reservoirs such as ElOptimal Sizing and Economical Analysis of PV-Wind Hybrid Power System for A. (Ninet Mohamed Ahme. A ISSN: 2088-8708 Arish dam and Terre valley Dam. Table 5 indicates the maximum monthly amount of rainfall in El-Arish recorded by the meteorological station in El-Arish . The latitude and longitude of this site is 31o 16' N and 33o 45' E respectively. The meteorological conditions during the year, i. , the yearly wind speed and solar radiation of this location are illustrated in Figure 4 and Figure5 respectively. The annual average solar radiation and the annual average wind speed obtained from the Egyptian solar radiation atlas are 5. 78 KWh/m2/day and 2. 1 m/s respectively . Table 5. The maximum monthly amount of rainfall in El-Arish Month Jan. Feb. Mar. Apr. May. Jun. Jul. Aug. Sep. Oct. Nov. Max. amount of rain. Figure 4. El-Arish yearly wind speed variation Dec Figure5. El-Arish yearly solar radiation variation ELECTRICAL LOAD ESTIMATION The energy required for the irrigation pump depends on the number of the irrigated acres, the amount of water per acre and the total head. Therefore, the first step for designing water irrigating system is to determine the daily amount of water required for the irrigating plant. Table 6 shows the amount of water required for irrigating one tree of olive per day at different months and different growth ages in Egypt . For irrigating ten acres of olive, we must calculate the number of trees of ten acres as follow: The required area for one tree growth is 4 my6 m = 24 m2 Number of trees per acre: 4026/24= 167. 75 tree /acre We assumed the number of trees per acre to be about 170 trees Number of trees for10 acres = 170*10 = 1700 trees Electrical load estimation is based on the maximum amount of water required for irrigating 10 acres of olive. It is observed that, the maximum amount of water required for irrigation is during the sixth year of Also, it is observed that the water demand is the highest during Apr-Sep. months, while it is the lowest during Nov-Feb. months as shown in Table 6. Accordingly, the amount of water required for irrigating 10 acres per day at different months is indicated in Table 7. The peak water requirement is selected for estimating the size of the irrigation pump which is needed for lifting this amount of water to a height of 10 meter. During the heavy rainy months (Nov. - Feb. ) the daily electrical load decreases, since the irrigation pump will be out of operation at all. Also, olive irrigation is needed only for a few hours a day. therefore, this pump operates only for five hours daily. In this study, the design of irrigation system is based on the following assumptions and criteria: Total irrigated area is 10 acres. Peak water requirement is 170 m3/day, number of irrigation hours is 5 hours/day . rom 6:00 AM to 9:00 AM and from 5:00 PM to7:00 PM), pump discharge rate is 34 m3/hour for pumping the water to a head of 10 meter. Based on these assumptions, it is found that the appropriate pump is ICH - ICH200/6BRM single-phase centrifugal pump . The specifications of this pump are given in Table 8. IJECE Vol. No. August 2017 : 1797 Ae 1814 IJECE ISSN: 2088-8708 The electrical energy consumption of the irrigation pumping system is 7. 5kWh per day. The total electrical load consists of an irrigation pump and some electrical appliances for the farmerAos house such as television, compact fluorescent lamps, ceiling fan, refrigerator and washing machine as indicated in Table 9. Figure 6 illustrates the daily load profile for a typical two days of winter and summer seasons. Table 6. The amount of water required for irrigating one tree/day of olive at different months and different growth ages in Egypt Ages by years More than 6 Jan. & Feb. Mar. Quantity of water by liter/ tree/day Apr. AiSep. Oct. Nov. & Dec. Table 7. The amount of water required for irrigating 10 acres per day Month Quantity of water . 3/da. Jan. - Feb. &Nov. - Dec. Mar. & Oct. Apr. Ai Sep. Table 8. Irrigation pump specifications Pump Model ICH200/6BRM Power(KW) Max. Max. Table 9. The daily electrical load requirement Load type No. of units Load power (W) Energy saving lamp No. of operation hours 10 AM -12 AM 7 PM -10 PM 7 PM -12 PM Outdoor lamp 7 PM - 6 AM Refrigerator 24 hour Washing machine 12 PM - 3 PM Ceiling fan 9 AM - 6 PM Pump 6 AM - 9AM 5 PM - 7 PM Figure 6. Hourly electrical load profile for a typical day in winter and a typical day in summer Optimal Sizing and Economical Analysis of PV-Wind Hybrid Power System for A. (Ninet Mohamed Ahme. A ISSN: 2088-8708 MATHEMATICAL MODELING OF RENEWABLE POWER SYSTEM COMPONENTS The mathematical models of the proposed three renewable power system components will be described in the following sections. PV Array Model Output electric power from PV module is given by the following Equation . PM A A M AM I r Where AM is the power conversion efficiency of the PV module. A M . is the surface area of PV module and Ir (W/m. is the solar irradiance. For PV generator, voltage and current of PV module is usually scaled-up by connecting PV modules in series and parallel to constitute the PV array. The output power of the solar PV array can be represented as follow . Parray A N s C N p C PM Where. Ns. Np and PM are the PV modules in series, parallel and the PV module power respectively. Wind Turbine Model Power output of the wind turbine generator at a specific site depends on wind speed at hub height and speed characteristics of the turbine. The power extracted from the wind turbine can be calculated using the following Equations . p wind A C p AAV wind Where. A is the air density . g/m. A is the rotor swept area . Vwind is the wind speed . and CP is the power coefficient of the wind turbine. Battery Model When there is an excess of energy produced by the PV generator and the wind turbine, after meeting the load demand this energy will be used to charge the battery bank and store it for future use. Equation . represents the total power generated by the PV array and the wind turbines at the time t . PG . ) A PPV . ) A PW . ) . During the charging process, when the total output of all generators exceeds the load demand, the available battery bank capacity at hour t can be described by . PBAT . ) A PBAT . A . A ( P G . ) A PL . )) . When the available power generated from the PV and wind generators is less than the load demand, the battery discharges, and therefore, the available battery bank capacity at time t can be expressed as . PBAT . ) A PBAT . A . A ( PL . ) A PG . )) . Where PBAT . is battery capacity at time t. PBAT . is battery capacity at an earlier time . ECONOMICAL MODELING The aim of this study is to achieve an optimally designed standalone renewable power system in terms of cost of energy and system power reliability. The best possible or optimum system configuration is the one that satisfies the user-specified constraints at the objective function. In this study the objective function is the minimization of total Net Present Cost (NPC) of renewable power system which can be represented by . , . IJECE Vol. No. August 2017 : 1797 Ae 1814 IJECE ISSN: 2088-8708 CT A Eu CI i A CM & Oi A CRi A CS i . i A1 Where CT is the total system cost, m is the number of energy sources used. CI i is the initial capital cost. CM&Oi is maintenance and operation cost. CRi is replacement cost and CSi is the salvage cost at the end of the project. In order to calculate the present value of the future expense for a single payment such as replacement cost and salvage value that occurring in a specific year n at given interest rate i, the following formula can be used . , . PF A A1 A i An . For accounting the present value of an annual expense such as operation and maintenance cost over a period of years n the following formulas can be used . , . PA A CRF The initial capital cost CIi is converted into annual capital cost A using the following capital-recovery factor (CRF) . , . A . n CRF A . A i ) n A 1 Where. PF and PA are the present worth for the sum of money for the single payment and annual payment respectively. F is the single payment. A is the annual payment, n is the project life time and CRF is the capital recovery factor which determines the periodic payment necessary to pay back that sum of money at interest rate i over n periods. The cost of energy (COE) is the cost of generating 1 kWh of energy utilized by the load, and can be calculated as follows . , . COE A TAC TALE Where TAC is the total annual cost and TALE is the total annual load energy. CONSTRAINS Genetic algorithm is used as optimization tool. where the objective function is to minimize the cost of the system over its 25 years of operation subject to power balance reliability constrains. For each time t, the total power of PV-wind -battery system, must supply the load (PL) demand with a certain reliability This relationship can be represented by . PPV A PW A PBAT C PL Constraints of battery capacity PBAT min C PBAT C PBAT max To keep the battery from being undercharged or overcharged, the battery state of charge (SOC) can not exceed the largest charge quantity and least charge quantity of battery. It must stay between the minimum and maximum state of charge. SOCmin and SOCmax, respectively. This can be described by the Equation . SOCmin C SOC C SOCmax Optimal Sizing and Economical Analysis of PV-Wind Hybrid Power System for A. (Ninet Mohamed Ahme. A ISSN: 2088-8708 The battery keeps at high state of charge, 100% as a maximum value and 40% as a minimum value. OPTIMIZATION METHODOLOGY The proposed sizing methodology for the cost minimization . bjective functio. of renewable power system is carried out using a genetic algorithms (GA) approach. GA is selected for power system optimization because it has shown to be highly applicable to cases of large nonlinear systems. it is emerging as popular method for the solution of complex engineering problems. GAs have been applied to the design of large power distribution systems and the solution of power economic dispatch problems because of their ability to handle complex problems with linear or non-linear cost functions both, accurately and efficiently. , . The GA possesses superior features that make it common for optimization purposes, especially for hybrid systems. Its performance for searching the global optimum is extremely efficient, and is very suitable for optimization problems of a great number of optimized parameters . GA Principles HOGA is a software package which used for optimizing both, the system components . ain genetic algorith. and the control strategy . econdary genetic algorith. GA is used to evaluate both conditions in minimizing the total net present cost for optimum configuration . GA is based on the principles of natural genetics and natural selection and uses three operators to imitate the natural evolution processes. operators: selection, crossover and mutation are used to evolve the population from its current generation to the next whose average fitness value should ideally be better. New generations are thus evolved from the knowledge of previous generations and since the fitter individuals in the population are the ones selected for crossover their good genes . ood solution. over time dominate the population and the algorithm converges to an optimum. With proper parameter selection. GAAos are capable of obtaining a suitable global optimum solution . GA Implementation The GA flowchart which is used in sizing calculation is depicted in Figure 7. GA selects individuals at random from the current population to be parents and uses them to produce the children for the next generation by using the three main operations, which are the selection, crossover, and mutation operations. Then, it can repeatedly modify a population of individual solutions, where, over successive generations, the population evolves toward an optimal solution. Implementation of the GA to find the best system parameters that met the objective function can be summarized in the following steps . , . Initially, the main algorithm randomly assigned a set of vectors Nm for sizing the hybrid system, each vectors representing a possible configuration of PV panels, battery and wind generator. The secondary algorithm is a GA that searches for the best control strategy for each combination of components in the main algorithm in order to minimize the NPC. The control strategy vector Nsec is randomly assigned by the secondary algorithm for each Nm vector, each vector representing a possible dispatch strategy in order to minimize the NPC. The Nsec vectors are evaluated by means of their aptitude. The Nest vectors have a greater probability of reproducing themselves, crossing with other vectors. each cross of two vectors, two new vectors are obtained . The descendents are evaluated and the best of them replace the worst individuals of the previous generation . To find the optimal solution and not to stay in local minimal, some solutions randomly change some of their components . The mutations can effect the change of the control strategy or the change of a bit of SOC set point . The individuals . obtained from reproduction and mutation is evaluated, making the next . The loop of generation is repeated . rom b to . until the best individuals identified and the determined number of generations (Ngen_main_ma. have been evaluated Nm solutions will have been obtained . ectors of the main algorithm with their optimal dispatch strategie. The Nm solutions are evaluated by means of their aptitude. Reproduction, crossing and mutation are carried out on the obtained solutions, making the next generation. Go to Step #2 and repeat the above steps sequentially until a determined number of generations (Ngen_sec_ma. have been evaluated. The best solution obtained is that which has the lowest value of NPC. IJECE Vol. No. August 2017 : 1797 Ae 1814 IJECE ISSN: 2088-8708 Figure7. Flow chart of the Genetic Algorithm (GA) SIMULATION RESULTS AND DISCUSSION For the proposed three system configurations. PV array and wind turbines represent the power While the battery bank is used for storing the surplus energy and supplying it when there is a deficit of available power to cover the load demands. The optimal simulation results have been obtained with the following values: main algorithm generations are 20, main algorithm populations are 20, secondary algorithm generations are 20, and secondary algorithm populations are 20, the crossover rate is 0. 9 and the mutation rate is 0. 1 The economical comparison between the three proposed renewable power systems was carried out by calculating the NPC of the proposed power systems in the two selected locations. The simulation results are discussed in the following sections. Abu AeRadius Location Standalone PV System Based on the optimization results, the optimal size of each component of standalone PV system is illustrated in Figure 8. The components type and their number are. the rated power of PV array is 1. 44 kW p . sC 9p of 80 Wp modul. , the battery bankAos rated capacity is 43. 7 kWh . sC19p battery with nominal capacity of 96 A. 20kW inverter. The battery charge regulator current is 407. 6A and the minimum SOC for the battery is 46% . ontrol strategy is to achieve minimum SOC for the battery at 40%). The optimal system NPC is $ 38122. The cost of the different components of this system as a percentage of the NPC is shown in Figure 9. It is observed that, the PV panels cost 26. 84% ($ 10. of the NPC, the battery bank has the largest share of 54. 23% ($20. and the inverter plus the auxiliary components e. charge regulator have cost of 18. 93% ($7. Optimal Sizing and Economical Analysis of PV-Wind Hybrid Power System for A. (Ninet Mohamed Ahme. A ISSN: 2088-8708 Figure8. Optimal unit size of standalone PV system Figure 9. Cost of the different elements in percentage of the total net present cost The annual energy balance of standalone PV system is described in Figure 10. The overall load energy is 8338 kWh/yr and the unmet load is 19. 8 KWh/yr. The convergence of NPC towards the optimum value as a function of the main algorithm generations is presented in Figure11. Also, this figure shows that there is no CO2 emission since the used renewable energy sources produce zero CO 2 during operation. Figure10. The annual energy balance of PV system Figure11. Net present cost versus the number of generations Standalone Wind System Figure 12 shows the optimal size of each component of standalone wind system. Based on the optimization results, the components type and their number in this system are. wind generator rated power is 21 kW . y3500 W of DC wind turbin. , the battery bankAos rated capacity is 33. 6 kWh . sC7p battery with nominal capacity of 200 A. 2 kW inverter. The battery charge regulator current is 830 A and the IJECE Vol. No. August 2017 : 1797 Ae 1814 IJECE ISSN: 2088-8708 minimum SOC allowed for the battery is 40%. The NPC of the standalone wind system is $65079. Figure 13 shows the cost of the different components of this system as a percentage of the NPC, it is observed that, the wind turbines have the highest share of 66. 42 % ($ 43. of the NPC, the battery bank shares by 17. ($11. and the inverter plus the auxiliary components share by 15. 65% ($10. Figure 14 shows the annual energy balance of wind system. The unmet load is 65. 1 KWh/yr. Figure 15 shows the convergence of NPC towards the optimum value as a function of the main algorithm generations. Figure12. The optimal unit size of standalone wind Figure13. Cost of the different elements in percentage of the total net present cost Figure14. The annual energy balance of standalone wind system Figure15. Net present cost versus the number of generations Standalone PV-Wind Hybrid System The optimal components size of PV--wind hybrid system is shown in Figure 16. Based on the optimization results, the components type and their number of this system are. the PV array rated power is Optimal Sizing and Economical Analysis of PV-Wind Hybrid Power System for A. (Ninet Mohamed Ahme. A ISSN: 2088-8708 5 kW . sC5p of 50 Wp modul. , the wind generator rated power is 2. 56kW . DC wind turbines of 640 W), the battery bankAos rated capacity is 25. 3 KWh . sC 11p battery with nominal capacity of 96 A. kW inverter. The battery charge regulator current is 218. 2A and the minimum SOC for the battery is 46%. The cost of the different components of this system as a percentage of the NPC is illustrated in Figure. The NPC is $37433, the PV generator shares by 10. % ($3870 ) of the NPC, the wind generator shares by 39. 42% ($ 14637 ), the battery bank shares by 34. 47% ($12. and the inverter plus the auxiliary components share by 15. 69% ($5825 ). It is observed that the battery bank and the wind generator are the most costly items. Figure 16. The optimal unit size of PV-wind hybrid system Figure 17. Cost of the different elements in the percentage of total net present cost Also, the contribution of individual system component participating in the hybrid system is shown in Figure 18. The major share of the energy comes from PV array . 8 kW. while the contribution of wind generator is small . and the unmet load is 135. 6 KWh/yr. The convergence of NPC towards the optimum value as a function of the main algorithm generations is indicated in Figure 19. Figure18. The annual energy balance of PV-wind hybrid system The PV-wind hybrid system with the lowest NPC is recognized as the most economically feasible option at Abu-Rudies location. It is recommended to utilize the hybrid PVAewind system for power generation in Abu-Rudies region rather than wind power system or PV power system alone. IJECE Vol. No. August 2017 : 1797 Ae 1814 IJECE ISSN: 2088-8708 Figure 19. Net present cost versus the number of generations El-Arish Location Standalone PV System Figure 20 shows the optimal size of standalone PV system components in El-Arish location. Based on the optimization results, the components type and their number of this system are. the PV array rated power is 1. 1 kWp . s y11p of 50 Wp modul. , the battery bankAos rated capacity is 43. 7 kWh . sy19p battery with nominal capacity of 96 A. 20 kW inverter. The battery charge regulator current is 259. 7A and the minimum SOC for the battery is 46%. The NPC is $ 35450. Figure 21 shows the cost of the different components of the system as a percentage of the NPC. It is observed that, the PV shares by 24. 22% ($ 8. the battery bank shares by 58. 38% ($20. and the inverter plus auxiliary components share by 4 %( $6. This study revealed that the major share of the cost is for the battery bank. The annual energy balance of standalone PV system is described in Figure 22. The unmet load is 163. 4 KWh/yr. Figure 23 illustrates the convergence of NPC towards the optimum value as a function of the main algorithm Figure 20. Optimal unit size of standalone PV system Figure 21. Cost of the different elements in percentage of the total net present cost Figure 22. Annual energy balance of PV system Optimal Sizing and Economical Analysis of PV-Wind Hybrid Power System for A. (Ninet Mohamed Ahme. A ISSN: 2088-8708 Figure 23. Net present cost versus the number of generations Standalone Wind System The optimal size of the standalone wind system components is shown in Figure 24. Based on the optimization results, the components type and their number are. the wind generator rated power is 45. 5 kW . y3500 W of DC wind turbin. , the battery bankAos rated capacity is 57. 6 kWh . sy12p battery with nominal capacity of 200 A. 2 kW inverter. The battery charge regulator current is 1219. 9A and the minimum SOC allowed for the battery is 58%. The NPC is $127450. Figure 25 shows the contribution of system components as a percentage of the NPC, the wind sharing is 73. 32 % ($ 93. , the battery bank shares by 16. 54% ($21. and the inverter plus the auxiliary components share by 10. 14% ($12. Figure 26 shows the annual energy balance of the standalone wind system. The unmet load is 343. 5 KWh/yr. Figure 27 describes the convergence of NPC towards the optimum value as a function of the main algorithm Figure 24. Optimal unit size of standalone wind system Figure 25. Cost of the different elements in percentage of the total net present cost Figure 26. Annual energy balance of wind system IJECE Vol. No. August 2017 : 1797 Ae 1814 IJECE ISSN: 2088-8708 Figure 27. Net present cost versus the number of generations Standalone PV-Wind Hybrid System The optimal size of the components of hybrid PV-wind system is shown in Figure 28. The components type and their number of this system are. the PV array rated power is1. 1kW . s y11p of 50 Wp modul. , the wind generator rated power is 0. 55kW . y 275 W of DC wind turbin. , the battery bankAos rated capacity is 41. 4 kWh . sy18p battery with nominal capacity of 96 A. 2 kW inverter. The battery charge regulator current is 264. 4A and the minimum SOC allowed for the battery is 46%. The NPC is $40696. Figure 29 shows the costs of the different components of the hybrid PV-wind system as a percentage of the total NPC, the PV shares by 20. 93 % ($8. of the total NPC, the wind generator shares by 14. ($ 5. , the battery bank shares by 49. 59%($20. and the inverter plus auxiliary components share by 12% ($6. The annual energy balance of the hybrid PV-wind system is shown in Figure 30. It is observed that, the major share of the energy comes from solar PV . 45 kW. while the contribution of wind generator is very small . The unmet load is 153. 3 KWh/yr. The convergence of NPC towards the optimum value as a function of the main algorithm generations is presented in Figure 31. Figure 28. Optimal unit size of hybrid PV-W system Figure 29. Cost of the different elements in percentage of the total net present cost Since the solar potential of El-Arish location is more than the wind capacity, energy production by standalone PV system has the lowest NPC. It is observed that, wind speed is relatively weak throughout ElArish area with an average value of 2. 1 m/s. It is too low to be used to produce the electrical energy in an economic manner. this can be confirmed by the highest NPC of the standalone wind system. The standalone PV system is the most economical and practical one. This can be attributed to the high average solar radiation 5 KWh/m2/day. The cost of hybrid system is between standalone PV and standalone wind systems. Table 10 summarizes the simulation results of the three suggested systemAo configurations including the optimal unit size of each component in the system, the optimal NPC and the cost of energy (COE) for the two locations under consideration. With respect to Al-Arish region, comparing the three system configuration with respect to NPC and COE , both the NPC and COE of the PV system is lower than those for both the hybrid PV- wind system and standalone wind system which could be attributed to the abundance of solar energy at this location. For Abu-Rudies. PV-wind system has the lowest NPC and COE compared to PV Optimal Sizing and Economical Analysis of PV-Wind Hybrid Power System for A. (Ninet Mohamed Ahme. A ISSN: 2088-8708 system and wind system. As the water irrigation demand is seasonal, therefore using the renewable power systems for powering other applications during the rest of the year make these systems more attractive and Figure 30. Annual energy balance of PV-wind system Table 10. Simulation results of sizing components and systems cost Abu-Rudies System (KW) Wind (KW) Battery . Total Net Present Cost (NPC) Cost of Energy (COE), $/KWh Standalone PV System --- $38128 $0. Standalone Wind System ----- $65079 $0. Hybrid PV-Wind System $37433 $0. El-Arish System (KW) Wind (KW) Battery . Total Net Present Cost (NPC) Cost of Energy (COE) $/KWh Standalone PV System ---- $35450 $0. Standalone Wind System --- $127450 $0. Hybrid PV-Wind System $40696 $0. IJECE Vol. No. August 2017 : 1797 Ae 1814 IJECE ISSN: 2088-8708 Figure 31. Net present cost versus the number of generations CONCLUSION Optimal sizing of system components is important in designing renewable power system. comparative study between three different system configurations (PV-battery standalone, wind -battery standalone and PV-wind-battery hybrid syste. for supplying an irrigating pumping system and a farmerAos house with the required electrical demand in two different regions is presented. HOGA simulation tool gives the best solution of all possible combinations. The best solution is determined with the help of GA. The NPC and the COE for each configuration is calculated and the combination with the lowest costs is selected to represent the optimal system. The simulation results verified that for El-Arish region, standalone PV system has the lowest system cost compared to cases where either only standalone wind system or hybrid PV-wind Also, simulation results revealed that a hybrid PV-Wind system was recognized the most economically feasible option for Abu-Rudies with the lowest COE as well as the NPC. The NPC of the optimal hybrid PV-wind and standalone PV systems configurations are $ 37433 and $35450 respectively. For the two considered locations, using wind generator as a standalone system to supply load is not economical or optimal choice because of low availability of wind potential in these two locations. REFERENCES