AGREGAT Vol. No. Mei 2018 ISSN : 2541 - 0318 [ Online ] ISSN : 2541 - 2884 [ Print ] PENGARUH PENAMBAHAN BAHAN ADMIXTURE CONSOL SG TERHADAP KUAT TEKAN BETON Arifien Nursandah . Satriyo utomo. Dio Alif Hutama. Prodi Teknik Sipil. Fakultas Teknik. Universitas Muhammadiyah Surabaya JL. Sutorejo No. 59 Kota Surabaya. Jawa Timur, 61135 E-mail: arifien. nursandah@gmail. Prodi Teknik Sipil. Fakultas Teknik. Universitas Muhammadiyah Surabaya JL. Sutorejo No. 59 Kota Surabaya. Jawa Timur, 61135 E-mail: satrioutomo64@gmail. Prodi Teknik Sipil. Fakultas Teknik. Universitas Muhammadiyah Surabaya JL. Sutorejo No. 59 Kota Surabaya. Jawa Timur, 61135 E-mail: dioalifhutama@ft. um-surabaya. Abstract Concrete is a building material that is very popularly used in the world of construction services, along with the rapid development of concrete technology has been successfully developed various innovation on additive material in concrete mixes to get good quality concrete. Consol SG is an additive material or admixture which is a product of liquid concrete plasticizers and high water reducing agents by regulating the effect of retarding, can increase workability without increasin g water content, reducing water without losing workability, and increasing compressive strength, and chloride free with no damaging on reinforcement. This research used an experimental method in a laboratory with a total of 60 samples of specimens, concrete compressive strength at 28 days with a cylinder diameter of 150 mm high by 300 mm with a variation of Consol SG mixture of 0%, 0. 2% and 0. 3% with high quality planned f'c = 30 MPa, on the effect of Consol SG addition on the compressive strength of the concrete which is viewed from the variation of Consol SG mixture. The results of the concrete compressive strength value of Consol SG 0. 2% is 31. 13 MPa . p to 2. 54% in terms of normal concret. , for the variation of Consol SG 0. 3% mixture of 32. 25 MPa . p to 6. 22% in terms of normal concret. While the variation of 0. 2% to 0. increased by . 59%). The test of the statistical model used is the Chi-Square test and the T-test using the SPSS software. Keywords: Additive. Consol SG. Compressive Strength of Concrete. Abstrak Beton merupakan bahan bangunan yang sangat populer digunakan dalam dunia jasa konstruksi, seiring pesatnya perkembangan teknologi beton telah berhasil dikembangkan berbagai inovasi bahan tambah dalam campuran beton agar mendapatkan beton yang berkualitas baik. Consol SG adalah bahan tambah admixtures atau additive merupakan produk plasticizer beton cair dan agen pereduksi air yang tinggi dengan mengatur efek perlambatan, dapat meningkatan kemampuan kerja tanpa meningkatkan kadar air, mengurangi air tanpa kehilangan kemampuan kerja, dan meningkatkan kuat tekan, serta bebas klorida yang tidak merusak pada tulangan. Penelitian ini menggunakan metode eksperimen dilaboratorium dengan total benda uji 60 sampel, kuat tekan beton pada umur 28 hari dengan diameter silinder ukuran 150 mm tinggi 300 mm dengan variasi campuran Consol SG sebanyak 0%, 0,2% dan 0,3% dengan mutu yang direncanakan fAoc = 30 MPa, pada pengaruh penambahan Consol SG terhadap kuat tekan beton yang ditinjau dari variasi campuran Consol SG. Hasil nilai kuat tekan beton pada campuran Consol SG 0,2% sebesar 31,13 MPa . aik 2,54% ditinjau dari beton norma. , untuk variasi campuran Consol SG 0,3% sebesar 32,25 MPa . aik 6,22% ditinjau dari beton norma. Sedangkan variasi 0,2% ke 0,3% naik sebesar . ,59%). Pengujian model statistik yang digunakan adalah uji Chi-Kuadrat dan uji T menggunakan aplikasi SPSS. Kata Kunci: Additive. Consol SG. Kuat Tekan Beton. PENDAHULUAN Beton merupakan bahan bangunan yang sangat populer digunakan dalam dunia jasa konstruksi, disamping materialnya yang mudah didapat juga kemudahan dalam pengerjaan merupakan salah satu keunggulan dari beton. Penggunaan beton menjadi pilihan utama karena beton terbentuk dari bahan campuran berupa agregat halus dan kasar serta bahan tambah admixture atau additivie, dengan menambahkan semen secukupnya berfungsi sebagai perekat bahan penyusun beton dan air sebagai bahan pembantu untuk proses reaksi kimia. Consol SG produk buatan anak bangsa, merupakan produk plasticizer beton cair dan agen pereduksi air yang tinggi dengan mengatur efek Consol SG digunakan sebagai bahan percampuran beton dengan tujuan menempatkan kondisi Pengaruh Penambahan. /Arifien N/hal. pada permukaann beton yang rata, beton yang dipompa, suhu tinggi, dan beton readymix serta area dimana volume besar harus ditempatkan pada satu waktu, dan Consol SG dapat menambah pengaturan waktu dalam cuaca panas, sehingga dapat meningkatan kemampuan kerja tanpa meningkatkan kadar air, mengurangi air tanpa kehilangan kemampuan kerja, dan meningkatkan kuat tekan, serta bebas klorida yang tidak merusak pada tulangan . Kimia kontruksi Indonesia. Berdasarkan uraian di atas maka dilakukan penelitian untuk mengetahui pengaruh penambahan Consol SG terhadap kuat tekan beton yang dihasilkan. AGREGAT Vol. No. Mei 2018 ISSN : 2541 - 0318 [ Online ] ISSN : 2541 - 2884 [ Print ] METODE PENELITIAN Penelitian ini adalah penelitian eksperimen dengan mengadakan suatu percobaan secara langsung untuk mendapatkan suatu data atau hasil yang menghubungkan antara variable-variabel yang diselidiki. Tahapan penelitian ditunjukkan pada gambar berikut: Gambar 3. 1 Bagan Alur Tahapan Benda Uji Benda uji yang digunakan dalam penelitian menggunakan silinder yang mempunyai ukuran diameter 150 mm dan tinggi 300 mm. Untuk benda uji berjumlah 60 sampel dimana setiap variasi terdiri dari 20 sampel uji kuat tekan normal dan penambahan Consol SG, sedangan pengujian dilakukan pada berumur 28 hari. Berikut adalah rincian benda uji dapat dilihat di Tabel 1. Tabel 1. Rencana benda uji No. Variasi Jenis Pengujian Kode Benda Uji Jumlah Beton Normal Kuat Tekan Silinder 0,2% Kuat Tekan Silinder 0,3% Kuat Tekan Silinder Consol SG Jumlah Total Benda Uji Sumber: Analisis Data . Keterangan: BN : Benda uji silinder mengunakan campuran normal. BC : Benda uji silinder mengunakan tambahan Consol SG. HASIL DAN PEMBAHASAN Berdasarkan analisis pengujian agregat yang telah semua memenui persyaratan SNI dan mix design telah melampaui kuat tekan yang direncanakan 30 MPa, maka untuk pengecoran sampel digunakan agregat kasar dari Situbondo dan agregat halus dari Badas Kediri. Pengaruh Penambahan. /Arifien N/hal. AGREGAT Vol. No. Mei 2018 ISSN : 2541 - 0318 [ Online ] ISSN : 2541 - 2884 [ Print ] Hasil Mix Design Beton Campuran Consol SG 1 m3 Tabel 2. Perhitungan Mix Design Consol SG 1 m3 Komposisi Satuan Air Semen Agregat Halus Agregat Kasar Consol SG Normal Consol SG 0,2% Consol SG 0,3% kg/m3 kg/m3 kg/m3 kg/m3 0,66 0,99 Jumlah kg/m3 Kadar Air % Penyerapan % 7,56 1,75 2,733 1,643 Force Pressure . N) Silinder Sumber: Analisis Data . Hasil Pengujian Kuat Tekan Beton Tabel 3. Rekapitulasi Hasil Pengujian Kuat Tekan Beton No. Kode Benda Uji BN-1 BN-2 BN-3 BN-4 BN-5 BN-6 BN-7 BN-8 BN-9 BN-10 BN-11 BN-12 BN-13 BN-14 BN-15 BN-16 BN-17 BN-18 BN-19 BN-20 BC0,2-1 BC0,2-2 BC0,2-3 BC0,2-4 BC0,2-5 BC0,2-6 BC0,2-7 BC0,2-8 BC0,2-9 BC0,2-10 BC0,2-11 Tanggal Pengecoran 29 April 2018 29 April 2018 29 April 2018 29 April 2018 29 April 2018 29 April 2018 29 April 2018 29 April 2018 29 April 2018 29 April 2018 30 April 2018 30 April 2018 30 April 2018 30 April 2018 30 April 2018 30 April 2018 30 April 2018 30 April 2018 30 April 2018 30 April 2018 01 Mei 2018 01 Mei 2018 01 Mei 2018 01 Mei 2018 01 Mei 2018 01 Mei 2018 01 Mei 2018 01 Mei 2018 01 Mei 2018 01 Mei 2018 02 Mei 2018 Pengujian 26 Mei 2018 26 Mei 2018 26 Mei 2018 26 Mei 2018 26 Mei 2018 26 Mei 2018 26 Mei 2018 26 Mei 2018 26 Mei 2018 26 Mei 2018 27 Mei 2018 27 Mei 2018 27 Mei 2018 27 Mei 2018 27 Mei 2018 27 Mei 2018 27 Mei 2018 27 Mei 2018 27 Mei 2018 27 Mei 2018 28 Mei 2018 28 Mei 2018 28 Mei 2018 28 Mei 2018 28 Mei 2018 28 Mei 2018 28 Mei 2018 28 Mei 2018 28 Mei 2018 28 Mei 2018 29 Mei 2018 Pengaruh Penambahan. /Arifien N/hal. Umur (Har. Slump Berat 12,78 12,75 12,75 12,69 12,69 12,65 12,70 12,78 12,78 12,80 12,68 12,77 12,70 12,81 12,70 12,70 12,76 12,78 12,75 12,81 12,83 12,65 12,65 12,69 12,75 12,65 12,84 12,87 12,78 12,64 12,84 Kuat Tekan g/cm. 305,92 303,04 303,04 297,27 300,15 305,92 297,27 305,92 305,92 314,58 300,15 303,04 300,15 308,81 303,15 300,15 303,04 305,92 308,81 303,04 314,58 305,92 305,92 308,81 311,70 305,92 314,58 317,47 311,70 305,92 314,58 (MP. 30,59 30,30 30,30 29,72 30,02 30,59 29,72 30,59 30,59 31,46 30,02 30,30 30,02 30,88 30,02 30,30 30,02 30,59 30,88 30,30 31,46 30,59 30,59 30,02 31,17 30,59 31,46 31,75 31,17 30,59 30,88 AGREGAT Vol. No. Mei 2018 No. Kode Benda Uji ISSN : 2541 - 0318 [ Online ] ISSN : 2541 - 2884 [ Print ] Tanggal Pengecoran BC0,2-12 02 Mei 2018 BC0,2-13 02 Mei 2018 BC0,2-14 02 Mei 2018 BC0,2-15 02 Mei 2018 BC0,2-16 02 Mei 2018 BC0,2-17 02 Mei 2018 BC0,2-18 02 Mei 2018 BC0,2-19 02 Mei 2018 BC0,2-20 02 Mei 2018 BC0,3-1 26 April 2018 BC0,3-2 26 April 2018 BC0,3-3 26 April 2018 BC0,3-4 26 April 2018 BC0,3-5 26 April 2018 BC0,3-6 26 April 2018 BC0,3-7 26 April 2018 BC0,3-8 26 April 2018 BC0,3-9 26 April 2018 BC0,3-10 26 April 2018 BC0,3-11 26 April 2018 BC0,3-12 26 April 2018 BC0,3-13 26 April 2018 BC0,3-14 26 April 2018 BC0,3-15 26 April 2018 BC0,3-16 26 April 2018 BC0,3-17 26 April 2018 BC0,3-18 26 April 2018 BC0,3-19 26 April 2018 BC0,3-20 26 April 2018 Sumber: Analisis Data . Pengujian 29 Mei 2018 29 Mei 2018 29 Mei 2018 29 Mei 2018 29 Mei 2018 29 Mei 2018 29 Mei 2018 29 Mei 2018 29 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 24 Mei 2018 Umur (Har. Slump Berat 12,87 12,75 12,69 12,88 12,75 12,87 12,86 12,75 12,84 12,75 12,78 12,72 12,74 12,87 12,85 12,86 12,84 12,85 12,88 12,92 12,85 12,75 12,90 12,90 12,81 12,92 12,84 12,86 12,86 Force Pressure . N) Silinder Kuat Tekan g/cm. 317,47 311,70 308,81 317,47 311,70 317,47 317,47 311,70 314,58 314,58 314,58 314,58 320,36 323,24 323,24 323,24 320,36 326,13 317,47 332,01 323,24 314,58 331,90 329,01 326,13 329,01 320,36 326,13 323,24 (MP. 31,75 31,17 30,88 30,75 31,17 31,17 31,75 31,17 31,46 31,46 31,46 31,46 32,04 32,32 32,32 32,32 32,04 32,61 31,75 32,90 32,32 31,46 33,19 32,90 32,61 32,90 32,04 32,61 32,32 Gambar 4. 3 Rekapitulasi Kuat Tekan Beton Umur 28 Hari Sumber: Analisis Data . Pengaruh Penambahan. /Arifien N/hal. AGREGAT Vol. No. Mei 2018 Dari diagram rekapitulasi ini dapat diketahui nilai kuat tekan beton untuk variasi campuran Consol SG semua keseluruhan mengalami peningkatan diitinjau dari kuat tekan beton normal. Pada kuat tekan campuran Consol SG 0,3% mengalami peningkatan paling tinggi sebesar 31,75 MPa pada uji sampel no. 8, 12, 15 dan 18. Sedangkan beton yang mengalami peningkatan paling tertinggi sebesar 33,19 MPa untuk variasi campuran Consol SG 3% pada uji sampel no. Hasil uji rekapitukasi ini terdapat kesamaan kuat tekan beton pada campuran Consol SG 0,2% dengan kuat tekan beton normal sebesar 30,59 MPa pada sampel no. 6 dan sebesar 30,88 MPa no. Sedangkan pada hasil rekapitulasi kuat tekan beton paling terendah ditunjukan pada sampel no. 9, 13, 15, 17 sebesar 30,02 untuk beton normal, untuk campuran Consol SG 0,2% kuat tekan beton paling rendah pada sampel no. 1 sebesar 30,02 MPa dan untuk campuran Consol SG 0,3% kuat tekan beton yang terendah terdapat pada sampel no. 1, 2, 3, 13 sebesar 31,46 MPa. Untuk kuat tekan beton yang tidak melampui 30 MPa atau gagal terdapat pada sampel no. 4 dan 7 sebesar 29,73 MPa. Gambar 4. 5 Grafik kuat tekan rata-rata beton dengan penambahan Consol SG umur 28 hari. Sumber: Analisis Data . Berdasarkan hasil pengujian diatas dengan penambahan Consol SG sebanyak 0,2% mempunyai kuat tekan beton sebesar 31,13 MPa dibandingkan beton normal dengan kuat tekan beton sebesar 30,36 MPa sehingga meningkatan sebanyak 2,54%. Pada beton dengan penambaan Consol SG sebesar 0,3% dengan kuat tekan beton sebesar 32,25 MPa meningkat menjadi 6,22% dari beton normal dengan kuat tekan beton sebesar 30,36 MPa, sedangakan perbandingan penambahan Consol SG 0,2% ke 0,3% Consol SG meningkat sebanyak 3,59%. Hal ini dapat dilihat pengunaan Consol SG 0,3% mempunyai kuat tekan paling tinggi. Pengaruh Penambahan. /Arifien N/hal. ISSN : 2541 - 0318 [ Online ] ISSN : 2541 - 2884 [ Print ] Uji Chi-Kuadrat Tabel 5. Hasil uji Chi-Kuadrat mengunakan campuran Consol SG Kode Benda Uji Kuat Tekan BN-1 BN-2 BN-3 BN-4 BN-5 BN-6 BN-7 BN-8 BN-9 BN-10 BN-11 BN-12 BN-13 BN-14 BN-15 BN-16 BN-17 BN-18 BN-19 BN-20 BC0,2-1 BC0,2-2 BC0,2-3 BC0,2-4 BC0,2-5 BC0,2-6 BC0,2-7 BC0,2-8 BC0,2-9 BC0,2-10 BC0,2-11 BC0,2-12 BC0,2-13 BC0,2-14 BC0,2-15 BC0,2-16 BC0,2-17 BC0,2-18 BC0,2-19 BC0,2-20 BC0,3-1 BC0,3-2 30,59 30,30 30,30 29,72 30,02 30,59 29,72 30,59 30,59 31,46 30,02 30,30 30,02 30,88 30,02 30,30 30,02 30,59 30,88 30,30 31,46 30,59 30,59 30,02 31,17 30,59 31,46 31,75 31,17 30,59 30,88 31,75 31,17 30,88 30,75 31,17 31,17 31,75 31,17 31,46 31,46 31,46 RataRata 30,36 31,13 32,25 ^2/e 0,002 0,000 0,000 0,013 0,004 0,002 0,013 0,002 0,002 0,040 0,004 0,000 0,004 0,009 0,004 0,000 0,004 0,002 0,009 0,000 0,004 0,009 0,009 0,040 0,000 0,009 0,004 0,012 0,000 0,009 0,002 0,012 0,000 0,002 0,012 0,000 0,000 0,012 0,000 0,004 0,020 0,020 ,95. ) 0,006 10,117 0,007 10,117 0,008 10,117 AGREGAT Vol. No. Mei 2018 ISSN : 2541 - 0318 [ Online ] ISSN : 2541 - 2884 [ Print ] Kode Benda Uji Kuat Tekan RataRata BC0,3-3 BC0,3-4 BC0,3-5 BC0,3-6 BC0,3-7 BC0,3-8 BC0,3-9 BC0,3-10 BC0,3-11 BC0,3-12 BC0,3-13 BC0,3-14 BC0,3-15 BC0,3-16 BC0,3-17 BC0,3-18 BC0,3-19 BC0,3-20 31,46 32,04 32,32 32,32 32,32 32,04 32,61 31,75 32,90 32,32 31,46 33,19 32,90 32,61 32,90 32,04 32,61 32,32 ^2/e . ,95. ) Sumber: Analisis Data . Dari tabel diatas dapat dilihat untuk benda uji sampel beton normal dan sampel beton tambahan Consol SG sampel dapat diterima semua dari x2 < x2 0,020 0,001 0,000 0,000 0,000 0,001 0,004 0,008 0,013 0,000 0,020 0,027 0,013 0,004 0,013 0,001 0,004 0,000 ,95. Uji T Satu Sampel Analisis uji T merupakan metode stastisik yang digunakan untuk menguji tingkat signifikan variasi Consol SG. Berdasarka hasil pengujian tabel diperoleh tingkat signifikan untuk variabel nilai t hitung < t tabel dan t hitung > t tabel, pengujian hipotesis dilakukan untuk mengetahui adakah pengaruh setiap variasi Consol SG 0,2% dan 0,3% terhadap rata-rata kuat tekan Hasil Pengujian Pada pengujian data variasi kuat tekan penambahan Consol SG sebesar 0,2% dan 0,3% terdapat pengaruh dari beton normal maka H1 diterima dan H0 Tabel 6. Hasil uji t beton campuran 0,2% One-Sample Statistics Beton Campuran 0,2% Mean 31,1270 Std. Deviation Std. Error Mean ,48107 ,10757 One-Sample Test Test Value = 31,13 Beton Campuran 0,2% Sig. -taile. Mean Difference -,028 ,978 -,00300 95% Confidence Interval of the Difference Lower Upper -,2281 ,2221 Sumber: Analisis Data . Pengaruh Penambahan. /Arifien N/hal. AGREGAT Vol. No. Mei 2018 ISSN : 2541 - 0318 [ Online ] ISSN : 2541 - 2884 [ Print ] Tabel 7. Hasil uji t beton campuran 0,3% One-Sample Statistics Beton Campuran 0,3% Mean Std. Deviation Std. Error Mean 32,2515 ,53524 ,11968 One-Sample Test Test Value = 32,25 95% Confidence Interval of the Difference Beton Campuran 0,3% ,013 Sig. -taile. Mean Difference ,990 ,00150 Lower Upper -,2490 ,2520 Sumber: Analisis Data . KESIMPULAN Penggunaan bahan tambah campuran Consol SG sebesar 0,2% dapat meningkatkan kuat tekan beton dari beton normal 30,36 MPa menjadi 31,13 MPa . aik 2,54%). Sedangkan variasi campuran Consol SG sebesar 0,3% dengan nilai kuat tekan sebesar 32,25 MPa . aik 6,22% dari beton norma. Campuran Consol SG 0,2% nilai t hitung < t tabel . ,28 < 2,. dan nilai Sign . ,978 > 0,. Sedangkan campuran Consol SG 0,3% nilai t hitung < t tabel . 13 < 2,. dan nilai Sign . ,990 > 0,. , maka H1 diterima dan H0 ditolak. Sehingga pada pengujian data variasi kuat tekan penambahan Consol SG sebesar 0,2% dan 0,3% terdapat pengaruh dari beton normal. SARAN Penelitian selanjutnya ditambahkan sampel dengan campuran lain sebesar 0,50% atau lebih agar dapat memperoleh campuran yang optimum. DAFTAR PUSTAKA